Function |
Preset Counter |
---|---|
Preset stages | 1stages |
Rated supply voltage | 100 to 240 VAC 50/60 Hz |
Digits | 4digits |
Mounting method | Flush mounting/Surface mounting |
External connection method | 11-pinSockets |
Function | Preset Counter |
---|---|
Preset stages | 1stages |
Rated supply voltage | 100 to 240 VAC 50/60 Hz |
Operating voltage range | 85% to 110% of rated supply voltage |
Power consumption | Approx. 12 VA (at 100 VAC) |
Counter (Count range) | 0~9999 |
Counter (Max. counting speed) | 30 Hz (Minimum counting input signal width: 16.7 ms (ON/OFF ratio: 1:1)) |
Counter (Input mode) | Increment |
Counter (Output modes) | N |
Counter (Reset system) | External and manual reset |
Input signal | Count / Reset / CP1 / CP2 |
Input method | No-voltage input |
No-voltage input (No-contact input) |
Short-circuit (ON) impedance: 1 kΩ Residual voltage: 2 V max. Open circuit impedance: 100 kΩ |
No-voltage input (Contact input) | Use a contact which can adequately switch 0.5 mA at 5 V. |
Minimum input signal width |
External reset: 20 ms Manual reset: 20 ms |
Control output (Contact output) |
SPDT Switching capacity: 3 A at 250 VAC/30 VDC, resistive load (cos phi=1) Minimum applicable load: 10 mA at 5 VDC (failure level:P reference value) |
Display method | 7-segment with LED display |
Digits | 4digits |
Character height |
Count value: 10 mm (Red) Zero suppression: Not equipped |
Prescaling function | Not provided |
Key protection | Not provided |
Teaching function | Not provided |
Batch counting function | Not provided |
Communications | Not provided |
Memory backup | Non-volatile memory (Number of rewite: 1000000 times min.Service life: Approx. 10 years min.) |
Surrounding air temperature |
Operating: -10 to +55 ℃ Storage: -25 to +65 ℃ |
Ambient humidity |
Operating: 35 to 85% Storage: 35 to 85% |
Insulation resistance |
100 MΩ min. (at 500 VDC) Between current-carrying terminals and exposed non-current-carrying metal parts / Between control output and operating circuit |
Dielectric withstand voltage |
Between current-carrying terminals and exposed non-current-carrying metal parts:2000 VAC 50/60 Hz for 1 min Between control output and operating circuit:2000 VAC 50/60 Hz for 1 min |
Impulse withstand voltage |
Between power terminals:6.0 kV Between current-carrying terminal and exposed non-current -carrying metal parts:6.0 kV |
Noise immunity |
Between power terminals:+/- 2k V Between input terminals:+/- 500 V Square-wave noise by noise simulator (Pulse width: 100 ns/1 us, 1-ns rise) |
Static immunity | 8 kV (malfunction) |
Vibration resistance (Destruction) | 10 to 55 Hz with 0.75 mm single amplitude for two hours each in three directions |
Vibration resistance (Malfunction) | 10 to 55 Hz with 0.5 mm single amplitude for ten minutes each in three directions |
Shock resistance (Destruction) | 300 m/s**2 three times each in six directions |
Shock resistance (Malfunction) | 100 m/s**2 three times each in six directions |
Mechanical life expectancy | 10,000,000 operations min. |
Electrical life expectancy | 100,000 operations min. (3 A at 250 VAC, resistive load) |
Degree of protection |
Case front: IP40 Case rear: IP40 Terminal block: IP00 |
Mounting method | Flush mounting/Surface mounting |
External connection method | 11-pinSockets |
Case color | Light gray (Munsell 5Y7/1) |
Weight | Approx. 110 g |
This website uses cookies (Learn more) and has a privacy policy (Learn more).