Model |
SL-V08H |
|||
Detection capability |
ø0.98" ø25 mm |
|||
Beam axis spacing/Lens diameter |
20 mm/ø5 mm 0.79"/ø0.20" |
|||
Effective aperture angle |
Max. ±2.5 ° (When operating distance is 3 m 98.23' or more) |
|||
Working distance |
0.1 m to 9.0 m 0.30' to 29.53' (detection height of 1,260 mm 49.61" or l ess) |
|||
Response time (ms) |
ON→OFF |
7*1 |
||
OFF→ON |
47*1 |
|||
Light source |
Infrared LED (850 nm) |
|||
Operation mode |
Turns on when no interruptions are present in the detection zone (excluding when the muting function is used) |
|||
OSSD output |
Output |
2 outputs each for PNP and NPN. Can be changed by using the connector cable. |
||
Max. l oad current |
500 mA*2 |
|||
Residual vol tage (during ON) |
Max. 2.5 V (with a cable length of 7 m 22.97') |
|||
Leakage current |
Max. 100 µA*3 |
|||
Max. capacitive load |
2.2 µF (with a load resistance of 100 Ω) |
|||
Load wiring resistance |
Max. 2.5 Ω*4 |
|||
Non safety-rel ated output |
AUX |
Output with automatic PNP/NPN switching function, 50 mA max. |
||
Interlock-reset-ready output |
||||
Alarm output |
||||
Clear/blocked output |
||||
State information output 1, 2 |
||||
Muting lamp output |
Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected |
|||
Input |
EDM input |
Short-circuit current 10 mA |
||
Wait input |
Short-circuit current 2.5 mA |
|||
Reset input |
||||
Muting input 1, 2 |
||||
Override input |
||||
Protection circuit |
Reverse current protection, short-circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC61496-1, EN61496-1, UL61496-1 |
|
EMC |
EN55011 Class A, FCC Part15B Class A |
|||
Safety |
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Rating |
Power voltage |
24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less |
||
Current consumption (mA) |
When the center indicator is ON |
Transmitter |
56*6 |
|
Receiver |
70*6 |
|||
When the center indicator is OFF |
Transmitter |
52*6 |
||
Receiver |
65*6 |
|||
Environmental resistance |
Enclosure rating |
IP65 (IEC60529) |
||
Overvoltage category |
II |
|||
Ambient light |
Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max. |
|||
Operating ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||
Storage temperature |
-25 to +60 °C -13 to 140 °F (No freezing) |
|||
Operating relative humidity |
15 to 85 % RH (No condensation) |
|||
Storage relative humidity |
15 to 95 % RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Main unit case |
Aluminum |
||
Upper case/lower case |
Zinc die-cast |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
150 g |
||
Receiver |
155 g |
This website uses cookies (Learn more) and has a privacy policy (Learn more).