Item | Specifications |
---|---|
Product Number | SF-C11 |
Part Number | SF-C11 |
Features | Less setup time for safety circuits |
Connectable light curtains | SF4B/SF2B series |
Supply voltage | 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
Current consumption | 100 mA or less (without light curtain) |
Fuse (power supply) | Built-in electronic fuse, Triggering current: 0.5 A or more, Reset after power down |
Enabling path | NO contact x 3 (13-14, 23-24, 33-34) |
Enabling path:Application category | AC-15, DC-13 (IEC 60947-5-1) |
Enabling path:Rated operation voltage (Ue) /Rated operation current (le) |
6 A / 30 V DC, 6 A / 230 V AC, resistive load (For inductive load, during contact protection) Min. applicable load: 10 mA (at 24 V DC) (Note) If several SF-C11 or SF-C13 units are being used in a line together, leave a space of 5 mm 0.197 in or more between each unit. |
Enabling path:Contact material / contacts | AgSnO, self cleaning, positively driven |
Enabling path:Contact resistance | 100 mOhm or less (initial value) |
Enabling path:Contact protection fuse rated | 6 A (slow blow) |
Enabling path:Mechanical lifetime |
10 million operations or more(switching frequency 180 operations/min.) (Note) Relay switching lifetime will vary depending on factors such as the type of load, the switching frequency, and ambient conditions. |
Enabling path:Electrical lifetime |
100,000 operations or more (switching frequency 20 operations/min., 230 V AC / 3 A resistive load) (Note) Relay switching lifetime will vary depending on factors such as the type of load, the switching frequency, and ambient conditions. |
Pick-up delay(Auto reset / Manual reset) | 80 ms or less / 90 ms or less |
Response time | 10 ms or less |
Auxiliary outputs | Safety relay contact (NC contact) x 1 (41-42) (Related to enabling path) |
Auxiliary output:Rated operation voltage / current | 24 V DC / 2 A, Min. applicable load: 10 mA (at 24 V DC) |
Auxiliary output:Contact protection fuse rated | 2 A (slow blow) |
Semiconductor auxiliary output(AUX) |
<Minus ground (Setting for PNP)> - Max. source current: 60 mA - Applied voltage: same as supply voltage (between the semiconductor auxiliary output and +V) - Residual voltage: 2.3 V or less (at source current 60 mA) Leakage current: 2 mA or less <Plus ground (Setting for NPN)> - Max. sink current: 60 mA - Applied voltage: same as supply voltage (between the semiconductor auxiliary output and 0 V) - Residual voltage: 1.5 V or less (at sink current 60 mA) Leakage current: 2 mA or less |
Semiconductor auxiliary output(AUX):Output operation | Related to auxiliary output of light curtain |
Overvoltage category | II |
Indicators:Power supply (Ui) | Green LED (lights up when the power is ON) |
Indicators:Enabling path [OUT] | Green LED (lights up when enabling contacts are closed) |
Indicators:Interlock (INTER_LOCK) | Yellow LED (lights up when enabling contacts are opened) |
Indicators:Fault (FAULT) | Yellow LED (blinks when fault occurs) |
External relay monitor function | Incorporated |
Trailing edge function | Incorporated |
Polarity selection function |
Incorporated (Sliding switch allows selection of plus / minus ground) Minus ground: Correspond to PNP output light curtain Plus ground: Correspond to NPN output light curtain (Note) Please switch the sliding switch to the PNP side for minus ground and to the NPN side for plus ground. |
Pollution degree | 2 |
Degree of protection |
Enclosure: IP40 Terminal: IP20 |
Ambient temperature | -10 to +55 degrees +14 to +131 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -25 to +70 degrees -13 to +158 degrees Fahrenheit |
Ambient humidity | 30 to 85 % RH, Storage: 30 to 95 % RH |
Vibration resistance | 10 to 55 Hz frequency, 0.35 mm 0.014 in amplitude in X, Y, and Z directions for twenty times each |
Connection terminal | Detachable spring-cage terminal |
Enclosure material | ABS |
Weight | Net weight: 320 g approx. |
This website uses cookies (Learn more) and has a privacy policy (Learn more).