| Actuator | Flexible rod (coil spring, high OF) |
|---|---|
| Sensitivity | Standard sensitivity |
| Operation type | General type |
| Operating mechanism | Snap action |
| Switching mechanism | Self-reset type |
| Contact method | Single-Pole, Double-Throw type |
| Contact form | SPDT |
| Contact gap | 0.5 mm |
| Terminal | Screw terminal (M4) |
| Load | General load |
| Rated current | 15A |
| Ratings (AC) Non-Inductive load |
Rated voltage: 125 VAC / Resistive load: 15 A(NC) 15 A(NO) / Lamp load: 2 A(NC) 1 A(NO) Rated voltage: 250 VAC / Resistive load: 15 A(NC) 15 A(NO) / Lamp load: 1 A(NC) 0.5 A(NO) |
| Ratings (AC) Inductive load |
Rated voltage: 125 VAC / Inductive load: 7 A(NC) 7 A(NO) / Motor load: 2.5 A(NC) 2 A(NO) Rated voltage: 250 VAC / Inductive load: 5 A(NC) 5 A(NO) / Motor load: 1.5 A(NC) 1 A(NO) |
| Ratings (DC) Non-Inductive load |
Rated voltage: 8 VDC / Resistive load: 15 A(NC) 15 A(NO) / Lamp load: 2 A(NC) 1 A(NO) Rated voltage: 14 VDC / Resistive load: 15 A(NC) 15 A(NO) / Lamp load: 2 A(NC) 1 A(NO) Rated voltage: 30 VDC / Resistive load: 2 A(NC) 2 A(NO) / Lamp load: 2 A(NC) 1 A(NO) Rated voltage: 125 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.4 A(NC) 0.4 A(NO) Rated voltage: 250 VDC / Resistive load: 0.2 A(NC) 0.2 A(NO) / Lamp load: 0.2 A(NC) 0.2 A(NO) |
| Ratings (DC) Inductive load |
Rated voltage: 8 VDC / Inductive load: 7 A(NC) 7 A(NO) / Motor load: 3 A(NC) 1.5 A(NO) Rated voltage: 14 VDC / Inductive load: 7 A(NC) 7 A(NO) / Motor load: 3 A(NC) 1.5 A(NO) Rated voltage: 30 VDC / Inductive load: 1 A(NC) 1 A(NO) / Motor load: 1 A(NC) 0.5 A(NO) Rated voltage: 125 VDC / Inductive load: 0.03 A(NC) 0.03 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO) Rated voltage: 250 VDC / Inductive load: 0.02 A(NC) 0.02 A(NO) / Motor load: 0.02 A(NC) 0.02 A(NO) |
| Ratings explanation | Lamp load has an inrush current of 10 times the steady-state current. Inductive load has a power factor of 0.4 Min. (AC) and a time constant of 7 ms Max. (DC). Motor load has an inrush current of 6 times the steady-state current. |
| Inrush current |
NC: 30 A NO: 15 A |
| Ambient temperature |
Operating : -10 to +60 ℃ Storage : -10 to 60 ℃ ( with no icing or condensation ) |
| Ambient humidity |
Operating: 35 to 95%RH Storage: 35 to 95%RH |
| Speed of permissible operation | 1 mm/s to 1000 mm/s |
|---|---|
| Permissible operating frequency (Mechanically) | 120 operations / 1 minute Max. |
| Permissible operating frequency (Electrically) | 20 operations / 1 minute Max. |
| Contact resistance | 15 mΩ (Initial value. Measuring method is voltage drop method at 1 A, 6 to 8 VDC.) |
| Insulation resistance |
Between each terminal of the same polarities: 100 MΩ min. Between live-metallic part and ground: 100 MΩ min. Between each terminal and non-live-metallic part: 100 MΩ min. (at 500 VDC Megger) |
| Dielectric strength |
Between each terminal of the same polarities: 1000 V min. Between live-metallic part and ground: 2000 V min. Between each terminal and non-live-metallic part: 2000 V min. (50/60 Hz for 1 min) |
| Mechanical durability | 1,000,000 operations Min. |
| Electrical durability | 100,000 operations Min. (rating load) |
| Vibration resistance (Malfunction) | Vibration frequency range: 10 to 20 Hz, Double amplitude: 1.5 mm, Malfunction: 1 ms max. at the free position and the total travel of 40 mm. |
| Shock resistance (Destruction) | 1,000 m/s**2 |
| Shock resistance (Malfunction) | Malfunction time is 1 ms Max. at the free position and the total travel of 40 mm at 50 m/s**2. |
| Degree of protection |
Drip-proof type IEC60529 (JEM): Equivalent to IP62 |
| Mounting Method | Mounting with screw |
| Pre-Travel (PT) | Reference value 20 mm max. |
|---|---|
| Over-Travel (OT) | Standard value 42 to 60 mm |
| Total travel (TT) | Standard value: 40 mm max. |


This website uses cookies (Learn more) and has a privacy policy (Learn more).