HIKARI POWER

OMRON H3Y-2 3MIN (24VDC) ราคา 640 บาท

฿640.00
OMRON H3Y-2 3MIN (24VDC) ราคา 640 บาท
เหลือ 0 ชิ้น
ซื้อเลย
หยิบลงตะกร้า
  • หมวดหมู่ : Omron
  • รหัสสินค้า : 000740

รายละเอียดสินค้า OMRON H3Y-2 3MIN (24VDC) ราคา 640 บาท

TIMER OMRON H3Y-2 3MIN (24VDC)

Time Ranges

 

Rated time Time setting range Rated time Time setting range
0.5 s 0.04 to 0.5 s 3 min 0.1 to 3 min
1 s 0.1 to 1 s 5 min 0.2 to 5 min
5 s 0.2 to 5 s 10 min 0.5 to 10 min
10 s 0.5 to 10 s 30 min 1 to 30 min
30 s 1.0 to 30 s 60 min 2 to 60 min
60 s 2.0 to 60 s 3 h 0.1 to 3 h
120 s 5.0 to 120 s --- ---

 

Ratings

 

Item H3Y-2(-0)/H3Y-4(-0)
Rated supply voltage 
*6 *7
100 to 120 (50/60 Hz), 200 to 230 VAC (50/60 Hz), 240 VAC (50/60 Hz), 
24 VAC (50/60 Hz) *1 
12, 24, 48, 125, 100 to 110 VDC *2 *3
Operating voltage range All rated voltages except 12 VDC: 85% to 110% of rated supply voltage 
12 VDC: 90% to 110% of rated supply voltage *4
Reset voltage 10% min. of rated supply voltage *5
Power consumption 100 to 120 VAC: 1.5 VA (at 120 VAC) 
200 to 230 VAC: 1.8 VA (at 230 VAC) 
240 VAC: 1.7 VA (at 240 VAC) 
24 VAC: 1.5 VA (at 24 VAC) 
12 VDC: 0.9 W (at 12 VDC) 
24 VDC: 0.9 W (at 24 VDC) 
48 VDC: 1.0 W (at 48 VDC) 
100 to 110 VDC: 1.3 W (at 110 VDC) 
125 VDC: 1.3 W (at 125 VDC)
Control outputs H3Y-2(-0): 
5 A at 250 VAC, resistive load (cosφ = 1) 
The minimum applicable load is 1 mA at 5 VDC (P reference value). 
Contact materials: Ag 
H3Y-4(-0): 
3 A at 250 VAC, resistive load (cosφ = 1) 
The minimum applicable load is 1 mA at 1 VDC (P reference value). 
Contact materials: Au-clad + Ag-alloy

 

*1. Do not use the output from an inverter as the power supply. Refer to Safety Precautions for All Times for details. 
*2. With DC ratings, single-phase full-wave rectified power sources may be used. 
*3. Only the H3Y-2 and H3Y-2-0 Series include 2-VDC models. 
*4. Use the Timer within 90% to 110% of the rated supply voltage (95% to 110% for 12 VDC) when using it continuously 
      under an ambient operating temperature of 50°C. 
*5. Set the reset voltage as follows to ensure proper resetting. 
        100 to 120 VAC:10 VAC max. 
        200 to 230 VAC:20 VAC max. 
        100 to 110 VDC:10 VDC max. 
*6. Refer to Safety Precautions for All Times when combining the Timer with an AC 2-wire proximity sensor. 