Componet Master module

Item Specification
Communications protocol CompoNet Network protocol
Types of communications Remote I/O communications (programless,constant sharing of data with Slave Units)and message 
communications (explicit message communications as required with Slave Units and FINS message 
communications as required with Controllers *1)
Baud rate 4 Mbps *2,3 Mbps,1.5 Mbps,93.75 kbps
Modulation Base-band
Coding Manchester code
Error control Manchester code rules,CRC
Communications media The following media can be used.*3 
Round cable I (JIS C 3306,2-conductor 0.75 mm2) 
Round cable II (JIS C3306 4-conductor 0.75 mm2) 
Flat Cable I (DCA4-4F10 Standard Flat Cable) 
Flat Cable II (DCA5-4F10 Sheathed Flat Cable)
Communications distance 
and wiring
Refer to Cable Types,Baud Rates,and Maximum Distances.
Connectable Master Units CompoNet Master Units
Connectable Slave Units CompoNet Slave Units
Maximum I/O capacity Word Slave Units:1,024 inputs and 1,024 outputs (2,048 I/O points total) 
Bit Slave Units:256 inputs and 256 outputs (512 I/O points total)
Maximum number of nodes Word Slave Units:64 input nodes and 64 output nodes 
Bit Slave Units:128 input nodes and 128 output nodes 
Repeater Units:64 nodes
Bits allocated per node 
address
Word Slave Units:16 bits 
Bit Slave Units:2 bits
Maximum number of nodes 
per trunk line or sub-trunk 
line
32 nodes (including Repeater Units)
Applicable node addresses Word Slave Units:IN0 to IN63 and OUT0 to OUT63 
Bit Slave Units:IN0 to IN127 and OUT0 to OUT127 
Repeater Units:0 to 63
Repeater Unit application 
conditions
Up to 64 Repeater Units can be connected per network.When Repeater Units are connected in series 
from the Master Unit,up to 2 extra segment layers can be created (i.e.,up to 2 Repeater Units are 
allowed between a Slave Unit and the Master Unit).
Signal lines Two lines:BDH (communications data high)and BDL (communications data low)
Power lines Two lines:BS+and BS -(power for communications and internal Slave Unit circuits) 
Power is supplied from the Master Unit or Repeater Units.
Communications power 
supply
24 VDC ± 10%
Connection forms Flat Cable at baud rate of 93.75 kbps:No restrictions 
Other cables or baud rates:Trunk line and branch lines
Connections for Slave Units and Repeater Units:T-branch or multidrop connections

 

 

*1. FINS message communications are supported by CJ-series Controllers only. 
*2. Drop-line connections are not supported with a baud rate of 4 Mbps, so Slaves with prewired cables (Bit Slaves) 
       cannot be used. 
*3. Round cable, Flat Cable, and Flat Cable II are all different types of cable. To use more than one type of cable at a 
        time, Repeater Units must be used to separate them on trunk lines and sub-trunk lines.