Ethernet I/P Module

Item Specifications
Model number CJ1W-EIP21
Type 100Base-TX *1
Applicable PLCs NJ-series, CJ (CJ1, CJ2) series, CP1H, and NSJ series PLCs.
Unit classification CJ-series CPU Bus Unit
Mounting location CPU Rack or Expansion Rack
Number of Units that can be 
mounted
NJ-series System: 4 max. (including Expansion Racks) 
CJ series System and NSJ series System: 8 max. (including Expansion Racks) *2 
CP1H System: 2 max.
CPU 
Unit 
words 
used
Allocated CIO Area 
words (CPU Bus 
Unit words)
25 words/Unit (one unit number's words)
These words contain control bits and flags, the target node PLC's operating and error 
information, Unit status, communications status, registered/normal target node 
information, and FINS/TCP connection status.
Allocated DM Area 
words (CPU Bus 
Unit words)
100 words/Unit (one unit number's words)
These words contain the IP address display/setting area.
User-set area Any usable data area words
Target node PLC's operating and error information, and registered/normal target 
node information
CPU Bus Unit 
System Setup
Not used.
Non-volatile memory within 
EtherNet/IP Unit 
(See note.)
The following settings are stored in the EtherNet/IP Unit's non-volatile memory. 
Note: Unlike the regular Ethernet Units, the CPU Bus Unit Setup Area in the CPU 
Unit is not used for these settings. 
1. Unit Setup (communications settings for the EtherNet/IP Unit, such as the IP 
address, DNS server settings, host name, baud rate, FINS/UDP settings, and FINS/ 
TCP settings) 
2. Tag data link settings (device parameters)
Transfer 
specifi- 
cations
Media access 
method
CSMA/CD
Modulation method Baseband
Transmission paths Star form
Baud rate 100 Mbit/s (100Base-TX)
Transmission media Shielded twisted-pair (STP) cable 
Categories: 100 Ω at 5, 5e
Transmission 
distance
100 m (distance between hub and node)
Number of cascade 
connections
There is no limitation when a switching hub is used.
Current consumption (Unit) 410 mA max. at 5 V DC
Weight 94 g max.
Dimensions 31 × 90 × 65 mm (W × H × D)
Other general specifications Other specifications conform to the general specifications of the CJ-series.

 

 

*1. If tag data links are being used, use 100Base-TX. Otherwise, 10Base-T can be used, but this is not recommended. 
*2. Up to seven EtherNet/IP Units can be connected to a CJ2H-CPU6[]-EIP. Up to two EtherNet/IP Units can be connected 
       to a CJ2M CPU Unit.