HIKARI POWER

Fluke 279FC I/B Wireless True RMS Thermal Multimeter with iFlex and extra battery ราคา58,852.03บาท

฿58852.03
Fluke 279FC I/B Wireless True RMS Thermal Multimeter with iFlex and extra battery ราคา58,852.03บาท
เหลือ 0 ชิ้น
ซื้อเลย
หยิบลงตะกร้า
  • หมวดหมู่ : FLUKE
  • รหัสสินค้า : 036759

รายละเอียดสินค้า Fluke 279FC I/B Wireless True RMS Thermal Multimeter with iFlex and extra battery ราคา58,852.03บาท

Fluke 279FC I/B Specifications

AC Voltage
Range/Resolution600.0/0.1 mV
6.000/0.001 V
60.00/0.01 V
600.0/0.1 V
1000/1 V
Accuracy45 to 65 Hz: 1.0 % + 3
65 to 200 Hz: 4.0% + 3
200 to 500 Hz: 15% + 3
AC mV
Range/Resolution600.0/0.1 mV
Accuracy45 to 500 Hz: 1.0% + 3
DC Voltage
Range/Resolution6.000/0.001 V
60.00/0.01 V
600.0/0.1 V
1000/1 V
Accuracy6, 60, 600 V: 0.09% + 2
1000 V: 0.15% + 2
DC mV
Range/Resolution600.0/0.1 mV
Continuity
Range/Resolution600/1 Ω
AccuracyMeter beeps at <25 Ω, beeper detects opens or shorts of 600 µs or longer
Resistance
Range/Resolution600.0/0.1 Ω
6.000/0.001 kΩ
60.00/0.01 kΩ
600.0/0.1 kΩ
6.000/0.001 MΩ
50.00/0.01 MΩ
Accuracy600 Ω: 0.5 % + 2
6 to 600 kΩ: 0.5 % + 1
50 MΩ: 1.5 % + 3
Diode Test
Range/Resolution2.000/0.001 V
Accuracy1% + 2
Capacitance
Range/Resolution1000/1 nF
10.00/0.01 µF
100.0/0.1 µF
9999/1 µF
Accuracy1000 nF to 100 µF: 1.2% + 2
9999 µF: 10% typical
AC Current
Range/Resolution999.9/0.1 A
2500/1 A (with iFlex)
Accuracy45 to 500 Hz: 3.0% + 5
Frequency
Range/Resolution99.99/0.01 Hz
999.9/0.1 Hz
Accuracy0.1% + 1
Input Characteristics
AC VoltageInput impedance (nominal): >10 MΩ <100 pF
Common mode rejection ratio (1 kΩ unbalance): >60 dB, DC to 60 Hz
Overload protection: 1100 V rms
DC VoltageInput impedance (nominal): >10 MΩ <100 pF
Common mode rejection ratio (1 kΩ unbalance): >120 dB at DC, 50 Hz or 60 Hz
Normal mode rejection: >60 dB at 50 Hz or 60 Hz
Overload protection: 1100 V rms
AC mV/DC mVInput impedance (nominal): >10 MΩ <100 pF
Common mode rejection ratio (1 kΩ unbalance): >120 dB at DC, 50 Hz or 60 Hz
Normal mode rejection: >60 dB at 50 Hz or 60 Hz
Overload protection: 1100 V rms
Resistance/CapacitanceOpen circuit test voltage: <2.7 V dc
Full scale voltage to 6 MΩ: <0.7 V dc
Full scale voltage 50 MΩ: <0.9 V dc
Typical short circuit current: <350 mA
Overload protection: 1100 V rms
Continuity/Diode TestOpen circuit test voltage: <2.7 V dc
Full scale voltage: 2.000 V dc
Typical short circuit current: <1.1 mA
MIN/MAX Recording Accuracy
AC Functions40 counts for changes > 900 ms in duration
DC Functions12 counts for changes > 350 ms in duration
Infrared Camera Temperature
Temperature Range14 to 392°F (-10 to 200°C )
Measurement Resolution0.1°C
Temperature MeasurementYes, centerpoint
Accuracy±5 °C or ±5 %, whichever is greater, at 25 °C (ambient) for target temperatures below 20 °C, add 0.05 °C for each °C
Emissivity0.95 fixed
Image Performance
Resolution102 x 77
Image Capture Frequency8 Hz
Detector TypeUncooled vanadium oxide
Thermal sensitivity (NETD)≤200 mK
Infrared Spectral Band7.5 to 14 µm
Distance to Spot162:1
Field of View36 x 27°
Focus MechanismFixed focus
Image Presentation
PaletteIronbow
Level and SpanAuto
Image Capture and Data Storage
Image CaptureImage available for review before a save
Storage MediumInternal memory stores up to 100 images
Image TransferFluke Connect®/SmartView®
File Formatis2
Display Size3.5" (8.9 cm) diagonal