| AC Voltage | |
| Range | 600.0 mV 6.000 V 60.00 V 600.0 V 1000 V |
| Resolution | 0.1 mV 0.001 V 0.01 V 0.1 V 1 V |
| Accuracy | 1.0 % + 3 from 45 Hz to 500 Hz 2.0 % + 3 from 500 Hz to 1 kHz |
| DC Voltage | |
| Range | 600.0 mV 6.000 V 60.00 V 600.0 V 1000 V |
| Resolution | 0.1 mV 0.001 V 0.01 V 0.1 V 1 V |
| Accuracy | 0.09 % + 2 0.09 % + 2 0.15 % + 2 |
| Continuity | |
| Range | 600 Ω |
| Resolution | 1 Ω |
| Accuracy | Meter beeps at <25 Ω, beeper detects opens or shorts of 250 µs or longer. |
| Resistance | |
| Range | 600.0 Ω 6.000 kΩ 60.00 kΩ 60.00 kΩ 600.0 kΩ 50.00 MΩ |
| Resolution | 0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ |
| Accuracy | 0.5 % + 2 @ 600.0 Ω 0.5% + 1 from 6.000 to 600.0 kΩ 1.5 % + 3 @ 50.00 MΩ |
| Diode Test | |
| Range | 2.000 V |
| Resolution | 0.001 V |
| Accuracy | 1 % + 2 |
| Capacitance | |
| Range | 1000 nF 10.00 µF 100.0 µF 9999 µF |
| Resolution | 1 nF 0.01 µF 0.1 µF 1 µF |
| Accuracy | 1.2 % + 2 from 1000 nF to 100 µF 10 % Typical @ 9999 µF |
| AC and DC Current | |
| Range | 60.00 mA 400.0 mA |
| Resolution | 0.01 mA 0.1 mA |
| Accuracy | AC: 1.5 % + 3 from 45 Hz to 1 kHz DC: 0.5 % + 3 |
| Frequency | |
| Range | 99.99 Hz 999.9 Hz 9.999 kHz 99.99 kHz |
| Resolution | 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz |
| Accuracy | 0.1 % + 1 |
| Min/Max Recording | |
| Accuracy | DC Functions: ±12 counts for changes >350 ms in duration AC Functions: ±40 counts for changes >900 ms in duration |
| General Specifications | |
| Maximum Voltage Between Any Terminal and Earth Ground | 1000 V DC or AC RMS |
| Fuse Protection from A Inputs | 0.44 A (44/100 A, 440 mA) 1000 V FAST Fuse Fluke Specified Part Only |
| Display (LCD) | Update Rate: 4/sec Volts, Amps, Ohms: 6000 Counts Frequency: 10,000 Counts Capacitance: 1,000 Counts |
| Battery Type | 3 x AA Alkaline Batteries, NEDA 15A IEC LR6 |
| Battery Life | 250 Hours Minimum |
| RF Communications | 2.4 GHZ ISM Band |
| RF Communication Range | Open Air, Unobstructed: Up to 20m Obstructed, Sheetrock Wall: Up to 6.5m Obstructed, Concrete Wall, or Steel Electrical Enclosure: Up to 3.5m |
| Temperature | Operating: -10 to 50°C Storage: -40 to 60°C |
| Temperature Coefficient | 0.1 x (Specified Accuracy)/°C (<18°C or >28°C) |
| Relative Humidity | 0 to 90% (0 to 35°C) 0 to 75% (35 to 40°C) 0 to 45% (40 to 50°C) |
| Altitude | Operating: 2,000 m Storage: 12,000 m |
| Electromagnetic Compatibility EMI, RFI, EMC, RF | EN 61326-1:2006, EN 61326-2-2:2006. ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249, FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE |
| Safety Compliance | ANSI/ISA 61010-1 / (82.02.01): 3rd Edition CAN/CSA-C22.2 No 61010-1-12: 3rd Edition UL 61010-1: 3rd Edition IEC/EN 61010-1:2010 |
| Certifications | CSA, FCC, CE |
| Ingress Protection (IP) Rating | IP54 |
| Pollution Degree | 2 |
| Dimensions | 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14") |
| Weight | 340 g (12 oz) |