| Fluke 87V | |
| Voltage DC | Max voltage: 1000 V Accuracy: ±(0.05% + 1) Maximum resolution: 10 µV |
| Voltage AC | Max voltage: 1000 V Accuracy: ±(0.7% + 2) True RMS AC bandwidth: 20 kHz with low pass filter; 3 db @ 1 kHz Maximum resolution: 0.1 mV |
| Current DC | Maximum amps: 10 A (20 A for 30 seconds maximum) Amps accuracy: ±(0.2% + 2) Maximum resolution: 0.01 µA |
| Current AC | Maximum amps: 10 A (20 A for 30 seconds maximum) Amps accuracy: ±(1.0% + 2) True RMS Maximum resolution: 0.1 µA |
| Resistance | Maximum resistance: 50 MΩ Accuracy: ±(0.2% + 1) Maximum resolution: 0.1 Ω |
| Capacitance | Maximum capacitance: 9999 µF Accuracy: ±(1% + 2) Maximum resolution: 0.01 nF |
| Frequency | Maximum frequency: 200 kHz Accuracy: ±(0.005% + 1) Maximum resolution: 0.01 Hz |
| Temperature | Operating: -4 to 131°F (-20 to 55°C) Storage: -40 to 140°F (-40 to 60°C) |
| Operating Altitude | 6561' (2000 m) |
| Dimensions | 7.9 x 3.9 x 2.05" (201 x 98 x 52 mm) |
| Weight | 0.8 lb (355 g) |
| PRV240 | |
| Output Voltage: 240 V AC RMS or DC | ±10 % ≥1 MΩ |
| Output Voltage: LoZ >3 kΩ load | 60 V AC typical; 50 V AC RMS minimum |
| LED Power Indicator | Turns on when output voltage is present |
| Battery | 4 x AA Alkaline batteries NEDA (24 A IEC LR03) |
| Battery Life | 5000 (5-second duration) test cycles with >1 MΩ load, 300 tests minimum with >3 kΩ load |
| Operating Temperature | -10 to +50°C |
| Operating Humidity | 0 % to 90 % (0 to 35°C) |
| Operating Altitude | 2000 m |
| Safety | IEC61010-1, IEC61010-2-030 |
| Certification | CSA-CUS, CE |
| Dimensions | 11.7 x 7.4 x 2.8 cm (4.6 x 2.9 x 1.1") |
| Weight | 8 oz (0.23 kg) includes batteries |


This website uses cookies (Learn more) and has a privacy policy (Learn more).